- Coated CCD detection system
 - Roller press CCD detection system
 - Roller Slitting Machine CCD Detection System/Labeling Machine
 - Pole slice CCD detection system
 - Independent wide CCD re-inspection machine
 - Tab forming equipment CCD system
 - Electrode burr detection
 - Power battery winding machine CCD detection system
 - Cutting and stacking machine CCD detection system
 - Power Bare Cell Appearance Inspection Machine
 - Power battery casing equipment/pre-spot welding
 - Power battery top cover welding inspection machine
 - Power battery sealing nail detection system
 - Inspection of the front six sides of the blue film of the power battery pack
 - Power battery aluminum shell, blue film appearance inspection machine
 - Finished battery appearance inspection machine
 - Power battery connector welding detection system
 - Blade Battery Measurement Dimension Measuring Machine
 - Power battery module Busbar testing machine
 - Power battery module size detection
 - Small power battery automatic FT test and air tightness testing machine
 - Copper foil appearance inspection
 - Aluminum foil appearance inspection
 - Diaphragm appearance inspection
 - Aluminum plastic film appearance inspection
 - Visual inspection of cylindrical aluminum shell
 - Appearance inspection of square aluminum shell
 
Roller press CCD detection system

Inspection and Calibration
· Spot check and calibration: Remind the spot check at the set time, if the check is not passed or the machine is locked if the check is not overtime.
· Defect spot inspection: Black dot film is used for spot inspection, which is pasted on the roller shaft.
· Size inspection: Black rectangular film is used for inspection, and the inspection sheet is pasted on the roller.
Automatic GRR
· According to the nested GRR mode, automatic GRR is developed. The software selects the automatic GRR mode, and after the data is collected, the CVS file is automatically generated.
Fool-proof function
· The CCD detection is not running, and the slitter cannot run.
· The software monitors key steps, and if there is any abnormality, it will alarm and stop.
· Key parameter changes are recorded in log files.
· After changing the material, the membrane roll number must be changed; if it is not changed under special circumstances, the advanced authority must be enabled.
· If there are more than 3 bad products in a row, the alarm prompts the staff to confirm the condition of the pole piece and check whether the CCD lens is contaminated.
· If the marking is abnormal, it will alarm and stop and prompt.